725A+ is a digital clamp meter to measure upto 600A AC (True RMS) & DC, with voltage, resistance, temperature, frequency, other parameters measurement and backlit LCD.

Overview:

  • 600AC/DC A True RMS 
  • 27mm jaw
  • 4000 count
  • Auto & Manual range
  • AC/DC V, AC/DC A 
  • Resistance, capacitance, frequency, duty, temperature
  • Continuity, Diode 

Features:

  • Inrush current measurement
  • NCV, Low Battery indication and auto-power off
  • Data hold
  • Polarity indication 
  • Type Digital Clamp Meter
Regular price Rs. 4,720.00 incl. taxes
Out of stock
Out of stock, contact us for lead time

Ready to work out of the box!

All our meters are delivered with essential accessories and easy-to-follow instructional manual. Unbox and start measuring with confidence!

Warranty and returns?

All our meters come with 12 month warranty against manufacturing defects. Please read our returns and refund policy for more information.

Got Questions? Feel free to get in touch.

Technical Specifications: 

Model

Metrix+ 725A+

Safety standard

IEC 61010-1, CAT III 600V

DC Voltage

Range

Resolution

Accuracy

400mV ~ 400V

0.1mV ~ 100mV

+(0.5% + 5)

600V

1V

+(0.5% + 5)

AC Voltage(True RMS)

Range

Resolution

Accuracy

400mV ~ 400V

0.1mV ~ 100mV

+(1.2% + 5)

600V

1V

DC Current

Range

Resolution

Accuracy

400A

100mA

+(2% + 10)

600A

1A

+(2% + 10)

AC Current (True RMS)

Range

Resolution

Accuracy

400A

100mA

+(2% + 10)

600A

1A

+(2% + 10)

Resistance

Range

Resolution

Accuracy

400Ω ~ 4MΩ

0.1Ω ~ 0.001MΩ

+(1% + 3)

 

40MΩ

0.01MΩ

+(1.5% + 5)

Capacitance

Range

Resolution

Accuracy

10nF

0.001nF

+(3% + 20)

100nF ~ 1mF

0.01nF ~ 100nF

+(3% + 5)

10mF

1uF

+(5% + 5)

Temperature

Range

Resolution

Accuracy

-50 ~ 300C

1C

+(1% + 5)

301 ~ 1000C

1C

+(1.9% + 15)

-58F ~ 600F

1F

+(1.2% + 6)

601F ~ 1832F

1F

+(1.9% + 25)

Frequency

Range

Resolution

Accuracy

100Hz ~ 40MHz

0.01Hz ~ 0.01MHz

+(0.5% + 3)

Duty Ratio

Range

Resolution

Accuracy

1% ~ 99%

0.1%

+(0.5% + 3)

Inrush current measurement

The peak current of a measurement window of 80ms is measured

Diode

Display of similar diode positive voltage.

Measuring condition: Positive DC electric current 1mA,

reverse DC voltage approximate 3V

Continuity

When the transited resistance is smaller than about 90Ω,the buzzer beeps. Test condition: Open-circuit voltage is about 0.5V.

Additional functionalities

Diode, continuity, NCV, backlight, low battery indication, auto power off, data hold

Display

4000 counts backlit LCD

Operating temperature

0C ~ 40C, 75% RH max

Storage temperature

-10C ~ 60C, 85% RH max

Power

2 X 1.5V AAA

Size & weight

213 x 80 x 35mm, approx. 240g(incl. battery)

Standard Accessories

Main unit, test leads, temperature probe, user manual, battery

 

 

Applications:

Digital clamp meters are versatile tools used across various industries for non-contact measurement of AC/DC current in wires, making them ideal for troubleshooting electrical systems, motor diagnostics, and verifying load balances in commercial and residential settings. They allow technicians to safely and quickly test high current levels without interrupting the circuit


Measuring Principle:

The measuring principle of a digital clamp meter depends on its type: AC-only models use electromagnetic induction (current transformer effect) to measure current flow, while AC/DC models (Hall Effect) measure the strength of the magnetic field surrounding the conductor. Both methods allow for non-contact and safe current measurement without breaking the circuit.