{"product_id":"coat-scope-27-5k","title":"Metrix+ Coat Scope 27-5k Coating Thickness Gauge 0-5000um F\/NF","description":"\u003ch4\u003e\u003cspan\u003eTechnical Specifications:\u003c\/span\u003e\u003c\/h4\u003e\n\u003ctable border=\"0\" cellpadding=\"0\" cellspacing=\"0\" width=\"458\" height=\"521\" style=\"width: 458px;\"\u003e\n\u003ctbody\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\" width=\"64\" style=\"width: 204.036px;\"\u003eModel\u003c\/td\u003e\n\u003ctd width=\"64\" style=\"width: 250.679px;\"\u003eMetrix+ Coat Scope 27-5k\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\" style=\"width: 204.036px;\"\u003eInternational Standard\u003c\/td\u003e\n\u003ctd style=\"width: 250.679px;\"\u003eIt meets the standards of both ISO 2178 and ISO 2361 as well as DIN, ASTM and BS. \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\" style=\"width: 204.036px;\"\u003eMeasuring principle\u003c\/td\u003e\n\u003ctd style=\"width: 250.679px;\"\u003eMagnetic induction(F) \u0026amp; Eddy current(NF)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\" style=\"width: 204.036px;\"\u003eDisplay\u003c\/td\u003e\n\u003ctd style=\"width: 250.679px;\"\u003e4 digits backlit LCD\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\" style=\"width: 204.036px;\"\u003eMeasuring range\u003c\/td\u003e\n\u003ctd style=\"width: 250.679px;\"\u003eF : 0 - 5000um (0 - 160mils)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\" style=\"width: 204.036px;\"\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 250.679px;\"\u003eNF : 0 - 3000um (0 - 120mils) \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\" style=\"width: 204.036px;\"\u003eAccuracy\u003c\/td\u003e\n\u003ctd style=\"width: 250.679px;\"\u003e±1-3%n or +2.5um\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\" style=\"width: 204.036px;\"\u003eResolution\u003c\/td\u003e\n\u003ctd style=\"width: 250.679px;\"\u003e0.1um(0~99.9um); 1um(over 100um)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\" style=\"width: 204.036px;\"\u003eMetric\/Imperial\u003c\/td\u003e\n\u003ctd style=\"width: 250.679px;\"\u003eSelectable\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\" style=\"width: 204.036px;\"\u003eMinimum curvature radius \u003c\/td\u003e\n\u003ctd style=\"width: 250.679px;\"\u003eF : 1.5mm(convex) ; 25mm(concave)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\" style=\"width: 204.036px;\"\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 250.679px;\"\u003eNF : 3mm(convex) ; 50mm(concave)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\" style=\"width: 204.036px;\"\u003eMinimum measuring area\u003c\/td\u003e\n\u003ctd style=\"width: 250.679px;\"\u003eDiameter 6mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\" style=\"width: 204.036px;\"\u003eMinimum thickness of substrate\u003c\/td\u003e\n\u003ctd style=\"width: 250.679px;\"\u003e0.3mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\" style=\"width: 204.036px;\"\u003eMemory storage and recall\u003c\/td\u003e\n\u003ctd style=\"width: 250.679px;\"\u003e99 groups of measurement\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\" style=\"width: 204.036px;\"\u003eStatistics\u003c\/td\u003e\n\u003ctd style=\"width: 250.679px;\"\u003eMax, min and avg value of readings\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\" style=\"width: 204.036px;\"\u003eAdditional features\u003c\/td\u003e\n\u003ctd style=\"width: 250.679px;\"\u003eLow Battery Indicator, Auto power off\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\" style=\"width: 204.036px;\"\u003ePower supply\u003c\/td\u003e\n\u003ctd style=\"width: 250.679px;\"\u003e2 x 1.5V AAA(UM 4) battery\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\" style=\"width: 204.036px;\"\u003eOperation environment\u003c\/td\u003e\n\u003ctd style=\"width: 250.679px;\"\u003eTemperature: 0 to 50℃ ;  Humidity: \u0026lt; 95%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\" style=\"width: 204.036px;\"\u003eSize \u0026amp; Weight\u003c\/td\u003e\n\u003ctd style=\"width: 250.679px;\"\u003e130mm × 65mm × 35mm; 90g(not including batteries)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\" style=\"width: 204.036px;\"\u003eStandard Accessories\u003c\/td\u003e\n\u003ctd style=\"width: 250.679px;\"\u003eCoating Thickness Gauge, F\/NF combine probe,  ‘0’ calibration blocks, standard foils, technical manual, hard carry case.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\" style=\"width: 204.036px;\"\u003eOptional Accessories\u003c\/td\u003e\n\u003ctd style=\"width: 250.679px;\"\u003ePC interface(cable and software)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch4\u003e\n\u003cspan\u003e\u003c\/span\u003e\u003cspan\u003eApplications:\u003c\/span\u003e\n\u003c\/h4\u003e\n\u003cp\u003e\u003cspan\u003eThis Gauge is designed for non-destructively measuring the thickness of coatings on ferrous and non-ferrous substrates. It can be used to measure thickness of paint, galvanizing layer, lacquer layer, porcelain enamel, phosphide layer, copper tile, anodizing layer, varnish, plastic coatings, powder, etc.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003ch4\u003e\u003cspan\u003eMeasuring Principle:\u003c\/span\u003e\u003c\/h4\u003e\n\u003cp\u003e\u003cspan\u003eThis instrument has a unique single external probe which uses the principle of electromagnetic induction to measure the thickness of non-magnetic coatings on magnetic substrates and eddy current principle to measure thickness of non-magnetic coatings on non-magnetic substrates. \u003c\/span\u003e\u003c\/p\u003e\n\u003ch4\u003e\u003cbr\u003e\u003c\/h4\u003e","brand":"Metrix+","offers":[{"title":"Default Title","offer_id":47347869319385,"sku":"METPCS275K","price":38940.0,"currency_code":"INR","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0762\/8980\/2457\/files\/CoatScope27-5k.jpg?v=1759341255","url":"https:\/\/metrixplus.shop\/products\/coat-scope-27-5k","provider":"Metrixplus Instruments","version":"1.0","type":"link"}